1.
Odovtos (En línea) ; 23(3)dic. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386561

ABSTRACT

ABSTRACT: The aim of the study was to investigate the fracture strength of different composite resins and the quantity of voids in conventional posterior composite, high- flow flowable composite, bulk-fill flowable composite, and fiber-reinforced composite. Forty-four caries-free, freshly extracted mandibular premolars were used for this study. Teeth were prepared for cavity and root canal treatment. Subsequently, root canal treatment was applied to the teeth and cavities in order to prepare them for restorations. The specimens were then divided into four groups: group-1: Estelite Posterior; group-2: Estelite Flow Quick High Flow; group-3: Estelite Bulk-fill Flow; group-4: everX Posterior. One specimen from each experimental group was examined using micro-CT to perform measurement of voids. The fracture strength values of high-flow flowable, bulk-fill flowable, fiber-reinforced, and conventional micro- hybrid composites were found to be similar (p=0.497). EverX Posterior showed the highest fracture strength values (841.1±149.4 N), followed by Estelite Bulk-fill Flow (822.8±170.8 N). Volume of voids (%) obtained from Micro-CT analysis revealed that restorations with high-flow liner or bulk-fill flowable exhibited more voids. The fiber-reinforced composite showed the lowest percentage volume of incorporating voids and the highest fracture strength results.


RESUMEN: El objetivo del estudio fue investigar la resistencia a la fractura de diferentes resinas compuestas y la cantidad de burbujas en resinas posteriores convencionales, resinas fluidas de alto flujo, resinas fluidas tipo bulk-fill y resinas reforzados con fibras. Cuarenta y cuatro premolares mandibulares libres de caries, recién extraídos, fueron usados para este estudio. Los dientes se prepararon para el tratamiento de conductos radiculares y las cavidades para prepararlos para las restauraciones. Los especímenes se dividieron en cuatro grupos: Grupo-1: Estelite Posterior; Grupo-2: Estelite Flow Quick High Flow; Grupo-3: Estelite Bulk-fill Flow; Grupo-4: everX Posterior. Un espécimen de cada grupo experimental fue examinado usando micro-CT para realizar la medición de las burbujas. Los valores de resistencia a la fractura de los compuestos de alto flujo, flujo de relleno, reforzados con fibra y microhíbridos convencionales fueron similares (p=0,497). EverX Posterior mostró los valores más altos de resistencia a la fractura (841,1±149,4 N), seguido de Estelite Bulk-fill Flow (822,8±170,8 N). El volumen de las burbujas (%) obtenido del análisis de Micro-TC reveló que las restauraciones con revestimiento de alto flujo o con flujo de relleno a granel presentaban más huecos. El compuesto reforzado con fibra mostró el menor porcentaje de volumen de incorporación de vacíos y los resultados más altos de resistencia a la fractura.


Subject(s)
Composite Resins/analysis , Flexural Strength
2.
Odovtos (En línea) ; 23(1)abr. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386510

ABSTRACT

Abstract: Purpose: The objective of this study is to evaluate and compare the microtensile bond strength (μTBS) of four different self-adhesive resin cements to a resin-based ceramic CAD/CAM block, at the baseline, and after subjecting them to 5,000 thermo-cycles.Materials and Methods: Four self-adhesive dual-cured resin cements; G-CEM LinkAce (GC EUROPE, Leuven, Belgium), RelyX U200 (3M ESPE, Seefeld, Germany), Maxcem Elite (Kerr, CA, USA), TheraCem (Bisco, Schaumburg, USA) were applied to Cerasmart CAD/CAM blocks (GC EUROPE, Leuven, Belgium). CAD/CAM blocks were sectioned into sticks and subjected to µTBS tests at 24 hours, and the other half were subjected to tests after 5000 thermo-cycles. The data were tested by one-way variance analysis (p<0.05). Results: The highest bond strength values were observed in TheraCem, followed by G-CEM LinkAce and RelyX U200, respectively (p<0.05). At the baseline, G-CEM LinkAce, RelyX U200, and Maxcem Elite showed statistically similar results. After 5,000 thermal-cycles, a significant decrease was observed in the bond strength values of G-CEM LinkAce (p<0.05). Conclusion: Between the adhesive cements used in the study, TheraCem showed the highest micro-tensile bond strength values both in the baseline (24h) results, and after the 5,000 thermal- cycle aging procedures.


Resumen: Propósito: Evaluar y comparar la resistencia adhesiva microtensil (μTBS) de cuatro cementos de resina autoadhesivos diferentes con un bloque CAD/CAM de cerámica a base de resina, antes y después de 5.000 ciclos de termociclado. Materiales y métodos: cuatro cementos de resina de doble curado autoadhesivos; G-CEM LinkAce (GC EUROPE, Lovaina, Bélgica), RelyX U200 (3M ESPE, Seefeld, Alemania), Maxcem Elite (Kerr, CA, EE. UU.), TheraCem (Bisco, Schaumburg, EE. UU.) fueron aplicados a bloques Cerasmart CAD/CAM (GC EUROPE, Lovaina, Bélgica). Los bloques CAD/CAM se seccionaron en barras y se sometieron a pruebas µTBS a las 24 horas, y la otra mitad se sometió a pruebas después de 5000 ciclos térmicos. Los datos fueron probados por análisis de varianza unidireccional (p<0.05). Resultados: Los valores más altos de fuerza de unión se observaron en TheraCem, seguido de G-CEM LinkAce y RelyX U200, respectivamente (p<0.05). En la línea de base, G-CEM LinkAce, RelyX U200, Maxcem Elite mostró resultados estadísticamente similares. Después de 5.000 procesos de ciclo térmico, se observó una disminución significativa en los valores de resistencia de la unión de G-CEM LinkAce (p<0.05). Conclusión: entre los cementos adhesivos utilizados en el estudio, TheraCem mostró los valores más altos de resistencia de la unión micro-extensible tanto en la línea de base (24 h) como después de 5,000 procedimientos de envejecimiento térmico.


Subject(s)
Dentin-Bonding Agents , Resin Cements/therapeutic use , Resins , Muscle Tonus